Testing and Verification: E5 Product Performance
This article provides a summary of third-party test data that verifies the performance of E5® admixtures across several key durability metrics. The following data is extracted from the official E5 Submittal Packages and demonstrates compliance with industry-standard testing protocols.
Applies to: E5® Internal Cure®, E5® Catalyst™
Abrasion Resistance
ASTM C944 - Standard Test Method for Abrasion Resistance
This test measures the mass loss of a concrete surface after being subjected to a standardized abrasive force. The results show that the combination of E5 Internal Cure® and E5 Catalyst™ significantly reduces material loss, indicating a much harder and more durable surface.
|
Test |
E5 INTERNAL CURE Mass Loss |
E5 INTERNAL CURE + E5 CATALYST Mass Loss |
|
LOSS AVERAGE |
1.2 g |
0.7 g |
Conclusion: The E5 system loses approximately 42% less material than concrete treated with E5 Internal Cure alone, and is more than 3.5 times more resistant to abrasion than the industry standard of 2.5g loss.

BS 8204: 1987 (Chaplin Abrasion Test)
This rigorous test classifies the wear resistance of concrete floors. The E5 Internal Cure® treated surface achieved the highest possible classification.
|
Wear Class |
Degree of Wear Resistance |
Maximum Wear Depth |
|
Special |
Extremely High |
0.055 mm |
|
AR1 |
Very High |
0.100 mm |
|
AR2 |
High |
0.200 mm |
|
AR3 |
Good |
0.400 mm |
Conclusion: With an overall mean wear depth of 0.045 mm, the E5-treated surface is classified as Special, making it suitable for the most demanding industrial environments with heavy, abrasive traffic.

Freeze-Thaw Durability
ASTM C666 - Resistance to Rapid Freezing and Thawing
This test measures a concrete sample's ability to withstand 300 cycles of freezing and thawing. The primary metric is the durability factor, with a minimum of 80 required for compliance.
|
Material |
Dosage |
Fresh Properties |
Freeze-Thaw Results |
|
E5 Internal Cure |
4.0 oz/100wt |
Air content: 4.0% |
Durability factor: 89 |
Conclusion: The E5 Internal Cure® treated concrete achieved a durability factor of 89, comfortably exceeding the minimum requirement of 80. This demonstrates its excellent performance in freeze-thaw environments, even with a lower-than-standard air content of 4.0%.
Moisture Retention & Curing
ASTM C309 & C1315
These standards measure the moisture retention capabilities of a curing compound. E5 Internal Cure® meets these requirements through its internal curing mechanism, eliminating the need for topical products.
ASTM F1869
This standard measures evaporation loss. E5 Internal Cure® demonstrates significant reduction in evaporation within the first 72 hours, confirming its effectiveness in retaining mix water for hydration.
Compliance & Warranty
- ASTM C494: E5 Internal Cure® meets the requirements for a Type S, Specific Performance Admixture.
- Lifetime Warranty: The E5 Moisture Mitigation System, which combines E5 Internal Cure® and E5 Catalyst™, is backed by a 10-year limited lifetime warranty against flooring adhesive failure due to moisture migration.